Machined impeller, bowl and coupling drive end of a vertical high-temperature molten salt pump
Coupling & Fan Drive end
Cooled discharge head and mounting plate of a high-temperature molten salt pump
Discharge head Above tank
ZGPV vertical long-shaft molten salt pump columns laid out in the workshop before assembly and tank installation
Long-shaft column Into the tank
2–1,600 m³/hflow range
350 mmax total head
850 °Cmax medium temperature
7.5 MPamax design pressure
01
Product range

Five molten salt pump families, one vertical platform

Every build below shares the same wet-end DNA: a vertical long-shaft arrangement that keeps the motor, coupling and bearings above the liquid, a cooled bearing zone, and a close-coupled bowl/impeller hydraulic submerged in the salt. What changes is the stage count, the setting depth, the wetted alloy and the duty — solar salt circulation in a CSP receiver, hot-salt transfer to a steam generator, or high-temperature nitrate service in a chemical plant. As a molten salt pump manufacturer since 1967, we configure each unit around your temperature, salt chemistry and tank geometry.

Best sellerZGPV vertical high-temperature molten salt pump assembly in workshop

Vertical High-Temperature Molten Salt Pump long shaft, single / two stage

The core of the range: a vertical long-shaft centrifugal pump for molten nitrate salt and other hot chemical media. An advanced bearing cooling system and a strengthened shaft give long service life at temperature. Two construction forms are offered to match the working condition. The workhorse for transferring salt between storage tanks and through the heat-transfer loop.

Flow2–1,600 m³/h Headto 350 m Temperatureto 850 °C Pressureto 7.5 MPa
Vertical multistage molten salt pump with intermediate column pipe

Vertical Multistage Molten Salt Pump high head, high pressure

For duties where a single impeller cannot reach the required pressure, stages are stacked in series in a diffuser-bowl column. Design, manufacture and testing follow API 610 practice for petroleum, petrochemical and natural-gas industries. The bearing zone is cooled so hot salt cannot degrade the lubricant, and interstage sleeves and bushings are renewable.

Flowto 800 m³/h Headto 350 m Stages2–12+ StandardAPI 610 / ISO 9906
CSP dutyCooled discharge head and mounting plate of a high-temperature molten salt pump

CSP Hot Salt Circulation Pump receiver & steam generator

Moves the hot salt stream in a concentrating solar power plant — from the receiver or hot tank to the steam generator that raises the steam for the turbine. Designed for continuous operation on solar salt (60% NaNO₃ / 40% KNO₃) around 290–565 °C, with thermal-transient capability and materials chosen for nitrate corrosion resistance. See our CSP application guide.

FluidSolar salt / nitrate Temperature290–565 °C DutyContinuous BuildVertical wet pit
Cold salt transfer pump motor and pump unit for CSP two-tank storage

CSP Cold Salt Transfer Pump low-temperature tank duty

Returns cooler salt from the cold tank back to the receiver and keeps the storage loop circulating. Lower salt temperature simplifies material selection, but the same vertical, self-draining philosophy applies: no trapped low points where salt can freeze during a shutdown. Steam or electric trace-heating can be specified for the discharge head and external pipework.

FluidSolar salt / HITEC Temperature150–290 °C Flowto 1,600 m³/h OptionHeat tracing
Molten salt heat transfer pump assembly for chemical process heating

Molten Salt Heat Transfer Pump chemical & industrial

Beyond power generation, the same platform handles high-temperature heat-transfer salts in chemical processing — nitrate/nitrite mixtures, caustic and other aggressive hot media. Used in melamine, phthalic anhydride, salt-making and alkali services. Also supplied as a high-temperature chemical transfer pump where the medium reaches up to 850 °C.

MediumNitrate / nitrite salt Temperatureto 850 °C ServiceChemical transfer SealPacking / mechanical

Need a configuration that is not listed? Stage count, column length, wetted materials, nozzle orientation and driver are engineered to order — send your duty data to the ZGPV engineering team.

B
At a glance

Compare the molten salt pump families

All five families share the same vertical wet-pit platform, but they are optimised for different points on the duty map. Use this table to shortlist the right molten salt pump before you send your datasheet. Figures are indicative; every unit is engineered to the exact duty.

FamilyBest forFlowHeadTemperatureConstruction
Vertical high-temperatureGeneral molten salt transfer & tank duty2–1,600 m³/hto 350 mto 850 °CSingle / two stage
Vertical multistageHigh head, long column liftto 800 m³/hto 350 mto 850 °C2–12+ stages
CSP hot salt circulationReceiver & steam generator feedto 1,600 m³/hto 250 m290–565 °CVertical wet pit
CSP cold salt transferCold tank return & receiver supplyto 1,600 m³/hto 200 m150–290 °CVertical wet pit
Molten salt heat transferChemical & industrial hot loops2–800 m³/hto 350 mto 850 °CSingle / multistage

Not sure which family fits? Send your flow, head, salt type and tank drawing to the ZGPV molten salt pump engineers — we will size it and return a curve.

Row of vertical high-temperature molten salt pumps assembled in ZGPV workshop
Finished high-temperature molten salt pumps ready for shipment
Complete pumps — vertical molten salt pump sets assembled, aligned and prepared for delivery.
Long-shaft vertical molten salt pumps in ZGPV assembly hall
Long-shaft builds — deep-column units laid out for make-up and head fitting.
Vertical molten salt pump motor, flexible coupling and cooled discharge head
Driver & head — vertical motor, flexible coupling and cooled discharge head.
02
Construction

Two assemblies, top to bottom

A molten salt pump is defined by where the hot liquid stops and the machine starts. The wet end — bowl, impeller, column and suction casing — lives inside the tank; the dry end — discharge head, bearings, coupling and motor — sits above the tank plate, away from the heat. Understanding these two assemblies explains most of the design rules that follow.

Dry end — above the tank

The discharge head carries the mounting plate, the thrust bearing, the shaft-sealing arrangement and the driver. Because the motor and bearings cannot tolerate molten-salt temperature, the head is thermally isolated and the bearing housing is actively cooled. Shaft-coupled fans or cooling jackets carry heat away; the packing or mechanical seal is kept cool and flushed.

  • Discharge head with mounting plate & discharge nozzle
  • Cooled thrust-bearing housing (typically kept below 90 °C)
  • Packing box or cartridge mechanical seal with flush
  • Flexible coupling and vertical motor (IEC / NEMA)

Wet end — inside the tank

The submerged assembly is intentionally simple: no oil, no elastomers and nothing that needs adjustment at temperature. The impeller and bowl are cast from heat-resistant alloy; line-shaft bearings are product-lubricated with hard-faced sleeves; the column is sized to keep shaft deflection and critical speed safely away from the operating point.

  • Closed impeller, keyed to a forged or strengthened shaft
  • Bowl / diffuser casing with renewable wear rings
  • Column pipe and line-shaft with product-lubricated bearings
  • Suction bell or strainer at the tank floor
B

Two construction forms

We offer two structural forms so the pump can be matched to the tank depth, the salt temperature and the maintenance strategy. Both preserve the same cooled-bearing philosophy and the same wetted materials.

FeatureForm A — single / two stageForm B — multistage column
HydraulicSingle impeller, high-flow low-to-medium head2–12+ stages in series, high head
Typical dutyTank transfer, circulation, heat transferReceiver feed, long-column lift, high pressure
Shaft supportShort submerged shaft, minimal line bearingsLong line shaft with product-lubricated bearings
CoolingCooled bearing housing + fanCooled bearing housing + forced jacket
Service accessPull the wet end through the tank nozzlePull the column in sections

Explore the official vertical high-temperature molten salt pump product page for the full component list and performance table.

Renewable energy concept — solar thermal power and molten salt heat storage
Powering the energy transition — concentrating solar thermal plants store renewable heat in molten salt, and vertical molten salt circulation pumps move that clean energy from receiver to steam generator.
Precision-machined rotor and long line shaft assembly, dynamically balanced with critical speed checked before assembly
Rotor & line shaft — precision-machined and dynamically balanced, with critical speed checked before assembly.
C
Component close-up

The parts that make a molten salt pump survive the heat

A high-temperature molten salt pump is only as good as its rotor, bearings and seal. These are the working parts behind every ZGPV vertical long-shaft molten salt pump — selected, machined and balanced for continuous service in hot nitrate salt.

Precision-machined rotor of a vertical high-temperature molten salt pump
Rotor assembly — closed impellers keyed to a strengthened shaft, dynamically balanced.
Long line shaft for a vertical molten salt pump
Line shaft — straightened and checked for critical speed before assembly.
Blue 3D cutaway rendering of a vertical molten salt pump showing impeller, bowl, column and cooled dry head
Cutaway — see how the submerged bowl, column and dry head fit together inside the heated tank.
Vertical TEFC electric motor driving a high-temperature molten salt pump
Vertical motor — TEFC vertical driver, F insulation, VFD-ready for variable molten salt duty.
Bearing used in a high-temperature vertical pump
Thrust bearing — cooled housing keeps the bearing below its temperature limit.
Shaft seal and bearing seat of a molten salt pump
Shaft seal — graphite-free packing or cool-flushed cartridge seal.
03
How it works

Why the pump lives on top of the tank

Molten salt is a liquid only above its freezing point — solar salt freezes near 238 °C and HITEC near 142 °C. It is hot, dense (roughly 1,800–2,000 kg/m³), aggressive to ordinary materials, and it conducts heat into anything it touches. A conventional horizontal pump on a hot tank would cook its seal and bearings. The vertical wet-pit arrangement is the practical answer.

1. Immerse the wet end

Only the bowl and impeller go into the salt. Submergence is set above the minimum required so that vortexing and air entrainment are avoided — with hot salt, effective NPSH is usually governed by submergence rather than vapour pressure.

2. Isolate the dry end

The long column physically separates the hot liquid from the motor. Heat conduction up the shaft and column is intercepted by cooling at the head, keeping thrust bearings and seals in their allowed temperature band.

3. Circulate the salt

In a CSP plant, the cold-salt pump sends salt to the receiver; heated salt returns to the hot tank; the hot-salt pump feeds the steam generator. The loop is continuously circulating during operation — see the U.S. DOE concentrating solar-thermal overview.

Four vertical high-temperature molten salt pump configurations in unified industrial-blue finish — long-shaft, suspended, multistage and turbine wet-end designs Click to enlarge full-size photo ↗
Four wet-end configurations at a glance — long-shaft, suspended, multistage and turbine arrangements in a unified industrial-blue finish. Only part of the photo is shown here; click to enlarge the full-size image. Each design keeps the bowl submerged while the motor and bearings stay above the tank.
B

Know the salt you are pumping

The two salts most often specified behave very differently. Getting the temperature window and freezing margin right is the first step of any molten salt pump selection.

PropertySolar saltHITEC salt
Composition (wt %)60% NaNO₃ / 40% KNO₃7% NaNO₃ / 53% KNO₃ / 40% NaNO₂
Freezing point~238 °C~142 °C
Upper service limit~565 °C (decomposition above ~600 °C)~450–500 °C
Typical CSP range290 °C cold / 565 °C hot150–395 °C in many test loops
Design implicationHeat tracing & freeze protection essentialLower freeze risk, nitrite chemistry to manage

Salt property data referenced from public SolarPACES and DOE / OSTI CSP technical literature; confirm the exact salt specification with your process designer.

C
The storage loop

Where the cold and hot salt pumps sit in a CSP plant

In a two-tank concentrating solar power plant, the molten salt is both the heat-transfer fluid and the storage medium. Two pump duties keep the loop moving. Getting both right is the difference between a plant that dispatches power after sunset and one that stops when the sun goes down.

Cold salt pump → receiver

Pumps ~290 °C salt from the cold tank up to the solar receiver or collector field, where it is heated. Low-temperature duty, but the highest flow — often the largest units in the plant.

Hot salt pump → steam generator

Pumps ~565 °C salt from the hot tank through the steam generator to raise steam for the turbine. This is the severe duty: maximum temperature, thermal transients and the strictest material choice.

Back to the cold tank

Cooled salt returns to the cold tank and the cycle repeats. Every line is heat-traced; the pumps are self-draining so the salt cannot freeze in a low point during a shutdown.

Learn more from the U.S. Department of Energy CSP overview and SolarPACES, the IEA's CSP technology network. Our own notes: molten salt pumps in CSP.

04
Selection guide

Specify a molten salt pump in five steps

A molten salt pump is selected on much more than flow and head. Work through these five steps and most of the engineering risk is removed before the inquiry is even sent.

1

Define the duty point

Flow, total head and the minimum continuous flow. State every operating case — rated, nominal, minimum and startup — plus the number of starts per day. For CSP, include the cold and hot salt cases separately.

2

Fix salt chemistry & temperature

Solar salt, HITEC or a proprietary mix? Give the composition, chlorides and particulate limits, the normal temperature and the maximum upset temperature. This drives wetted materials and the freeze-protection strategy.

3

Set the submergence & NPSH

With near-zero vapour pressure, minimum submergence governs. Provide the tank level range, sump diameter and the lowest level at which the pump must still run, so the bell mouth and vortex behaviour can be checked.

4

Choose wetted materials

Select the bowl, impeller, shaft and column alloys against nitrate corrosion at your temperature. Ask for 3.1 / 3.2 material certificates and, for castings, MT/PT and MSS SP-55 visual inspection.

5

Specify driver & protections

Motor rating with margin for end-of-curve flow and maximum salt density, a VFD where the duty varies, and a cooled thrust bearing sized for the full hydraulic load. Define the shaft seal — graphite-free packing or a cool-flushed cartridge mechanical seal — plus heat tracing on every pocket that can freeze, vibration and temperature instrumentation, and the acceptance test standard (Hydraulic Institute / ISO 9906). For solar-salt service also state the instrument ranges, alarm and trip set points, and whether condition monitoring is required for critical CSP or long-duration storage duties.

Assembled vertical molten salt pump with column, discharge head and driver in the ZGPV workshop
Match the build to the tank — column length, submergence and head construction are fixed by your tank drawing and duty point, not by a catalogue model number.
Flexible coupling and cooled discharge head of a vertical high-temperature molten salt pump
Driver & protections — cooled thrust bearing, flexible coupling and graphite-free sealing are specified together with the motor rating for hot-salt service.

Testing and acceptance are commonly agreed to Hydraulic Institute standards and ISO 9906; pressure-containing parts follow ASME B31.1 where specified by the EPC.

B
Worked example

From a duty point to a molten salt pump model

A typical CSP hot-salt duty looks like this. It shows why flow and head alone are not enough — the salt and the tank decide the rest of the specification.

Input from the clientWhat we turn it into
23.5 m³/h at 21 m TDH, salt 384–395 °CVertical single-stage wet-pit pump, WC6 wet end, 4140 shaft, VFD motor sized with 25% margin
Salt: HITEC (7/53/40 nitrate/nitrite), chloride <100 ppmConfirm carbon-steel column acceptable; graphite-free packing; N₂-purged stuffing box
Tank floor 3.71 m below mounting plate, pump hung from steelColumn length 3.71 m, discharge head with mounting plate, self-draining layout, no low points
24 starts/day, 25-year life, thermal cycling 185 → 395 °CFatigue / creep assessment, cooled thrust bearing, flexible coupling,rt dynamic check
CE marking to EU 2023/1230, PED 2014/68/EUEU Declaration of Conformity, technical file, 3.1 / 3.2 material certificates

This is the sort of back-and-forth we handle every week. Send whatever data you have — even a rough process sketch — and the ZGPV engineering team will fill the gaps.

05
Configurations

VS1, VS4, VS4+ and VS5 — four ways to configure a vertical molten salt pump

Vertical molten salt pumps are not one machine. They are a platform of configurations matched to tank depth, flow, head and salt temperature. The four arrangements below are the industry's common reference points; ZGPV builds the equivalent wet-end and column designs for each duty, from high-flow circulation to deep-tank, high-head receiver feed. Choosing the right configuration early is the single biggest lever on reliability and lifecycle cost.

VS1 — vertical long-shaft, high-flow circulation

A vertical long-shaft arrangement built for large-volume circulation and demanding heat-transfer systems. The impeller runs submerged in the salt while the motor and thrust bearing stay above the tank, so the wetted end carries no oil, no elastomers and no adjustment points. This is the workhorse configuration for solar-salt receiver loops and large thermal-storage tanks.

  • Best for: high flow, low-to-medium head, deep tanks
  • Single or two-stage impeller; long product-lubricated line shaft
  • Typical media: binary solar salt, HITEC, ternary nitrate mixtures

VS4 — vertical suspended, medium duty

A vertical suspended pump suited to medium flow and medium head duties. The bowl assembly hangs from the discharge head inside the tank, with a short wetted shaft and a cooled bearing housing above the plate. It is the practical choice for transfer, circulation and heat-transfer services where a full long-shaft column is more than the duty needs.

  • Best for: medium flow and head, moderate tank depth
  • Short submerged shaft; cartridge seal or packed box at the head
  • Typical media: nitrate salts, heat-transfer salts, hot oils

VS4+ — enhanced suspended, severe service

An upgraded suspended design for severe operating conditions — higher temperature, more aggressive salt chemistry or tighter run-time requirements. Enhanced bearing protection, upgraded metallurgy and improved cooling extend service intervals where a standard suspended pump would need frequent attention.

  • Best for: corrosive salts, higher temperature, continuous duty
  • Upgraded alloy wetted parts; reinforced thermal isolation
  • Optional temperature and vibration condition monitoring

VS5 — vertical turbine, heavy-duty circulation

A heavy-duty vertical turbine configuration for specialised molten salt circulation systems that need higher head from a compact bowl diameter. Multiple stages stack in series inside the tank column, letting the pump meet receiver-feed or long-column lift duties without a horizontal pump and its difficult hot sealing.

  • Best for: high head, high pressure, receiver feed
  • 2–12+ stages in series; product-lubricated stage bearings
  • Typical media: binary/ternary salts, fluoride and chloride salts
Vertical long-shaft molten salt pump configuration families VS1 VS4 VS4+ VS5 in the ZGPV workshopClick to enlarge full-size photo ↗
Configuration families — long-shaft, suspended, multistage and turbine arrangements share one cooled dry-end philosophy. The preview shows a detail; click the photo for the full workshop image.
ConfigurationFlow rangeHeadStructureWhere it fits
VS1 long-shaftup to 3000 m³/hlow–mediumSubmerged bowl + long line shaftLarge CSP loops, storage tanks
VS4 suspended2–800 m³/hmediumHung bowl + short wetted shaftTransfer, circulation, process heat
VS4+ enhanced2–800 m³/hmediumHardened suspended designAggressive salts, continuous duty
VS5 turbine10–1600 m³/hup to 500 mMultistage vertical columnReceiver feed, high-head lift

Flow and head figures are indicative configuration envelopes. Final selection depends on salt type, operating temperature, tank depth and system curve — send us your duty point for a sized proposal.

Vertical long-shaft molten salt pump bodies on the workshop floor, wetted end runs fully submerged
Vertical long-shaft molten salt pump bodies — the wetted end runs fully submerged.
Multistage vertical turbine bowl stack with line shaft for high-head molten salt service
Multistage bowl stack — stacked impellers inside the submerged column deliver high head where pressure and temperature both run high.

Technical background: configuration families follow layout principles described in recognised industry standards such as API STD 610 and the Hydraulic Institute resources; all specifications above are ZGPV's own build envelopes.

06
Comparison

Vertical molten salt pump vs the alternatives

Why not use a standard horizontal centrifugal pump, or a submersible? The short answer is temperature, sealing and freeze protection. For hot nitrate salt, a vertical molten salt pump keeps the driver dry and the seal cool, drains completely when stopped, and lifts directly out of the tank for maintenance. A horizontal process pump exposes its mechanical seal to 400–565 °C salt; a submersible puts its motor in the liquid. That is why CSP plants and high-temperature chemical services standardise on the vertical long-shaft arrangement.

CriterionVertical molten salt pumpHorizontal process pumpSubmersible pump
Motor positionDry, above the tank — protected from heatDry, at grade — needs a flooded suction or liftSubmerged with the motor in the liquid
Sealing at 400–565 °CPacking / cool-flushed seal in the headMechanical seal exposed to hot salt — short lifeNo shaft seal, but motor cooling is critical
Tank drainageSelf-draining wet end; no trapped saltSuction piping can hold salt and freezePump stays in the liquid when drained
Maintenance accessLift the assembly from the tank topInline access, but seal work near hot pipingFull retrieval required for any service
Best forLarge heated tanks, CSP, high-temperature transferCooler, clean duties with stable suctionDeep sumps, lower-temperature liquids
ZGPV machining workshop finishing a long pump shaft on a lathe
In our own workshop — shafts, bowls and columns are finish-machined in-house, so critical fits and material traces stay under one roof.
ZGPV pump manufacturing hall with gantry cranes and machine tools
One roof, full control — casting review, machining, assembly and run test happen on the same production floor before a vertical molten salt pump ships.
07
Materials

Alloys matched to the salt, not the catalogue

Nitrate salts are corrosive to carbon steel at temperature, and the rate climbs with both temperature and chloride contamination. Wetted parts are selected as a set — casing, impeller, shaft and column — so they expand and wear predictably together.

ComponentStandard materialUpgrade optionWhy
Bowl / casingASTM A217 WC6 (Cr-Mo cast steel)CF8M / CD4MCu stainless, duplexNitrate corrosion resistance at temperature
ImpellerWC6 or stainless cast alloyDuplex stainlessStrength plus corrosion/erosion resistance
ShaftAISI 4140 / 42CrMo strengthened steel17-4PH, duplexTorsion and deflection control at 400 °C+
Column & discharge pipeASTM A106 Gr BA335 P11 / P22, stainless cladHigh-temperature allowable stress
Wear rings & bushingsHard-faced / Stellite-facedTungsten carbideGalling resistance in a dry-start event
Seal areaGraphite-free packingMechanical seal with cool flushAvoid graphite contact with nitrate salt

All wetted materials can be supplied with EN 10204 3.1 certificates (3.2 for pressure parts). Discuss the exact salt analysis with our engineers — chloride level often decides whether carbon steel is acceptable at all.

B
Made in our works

From casting to finished molten salt pump

Material selection is only the start. How the alloy is cast, machined, heat-treated and assembled decides whether a high temperature molten salt pump lasts a season or a quarter century. These are the stations every unit passes through in the ZGPV workshop.

Machined closed impeller of a high-temperature molten salt pump
Impeller machining — closed impellers cast in WC6 or stainless, then finish-machined and balanced.
Interior of a molten salt pump bowl and diffuser casing
Bowl & diffuser — renewable wear rings, checked clearances, smooth passages for hot salt.
Technicians assembling a vertical high-temperature molten salt pump
Assembly — line shaft, column sections and head aligned by experienced fitters.
Discharge flange of a high-temperature molten salt pump
Discharge nozzle — ASME B16.5 Class 300 RTJ or to the project interface drawing.
Flexible coupling for a vertical molten salt pump
Coupling — flexible, non-lubricated spacer type; thrust taken by the pump bearing.
Engineering section drawing of a vertical molten salt pump
Engineering — thermal, critical-speed and clearance calculations behind every build.
08
Ultra-high temperature

What changes when the salt reaches 700 °C

Above roughly 600 °C a nitrate or chloride salt stops behaving like a conventional heat-transfer fluid. It becomes aggressive and thermally unstable, and it attacks the three things a normal pump relies on: clearances, lubricants and seals. Tower-type CSP, long-duration thermal storage and advanced hybrid power projects are pushing duty points into this 650–700 °C band, where a molten salt pump is no longer a catalogue item but an engineered system.

A

Four problems a 700 °C pump has to solve

Each of these failure modes is manageable on its own. The engineering challenge is solving all four at once, for thousands of hours of continuous base-load operation.

Extreme thermal stress

Casings, impellers and shafts expand, warp and lose clearance. Uncontrolled, distortion shows up first as rubs and vibration, then as cracked welds.

Corrosion & oxidation

Molten nitrate and chloride salts aggressively attack ordinary stainless steels. Corrosion products contaminate the salt and roughen flow passages, cutting efficiency.

Seal & bearing failure

Elastomers, oils and conventional packing break down well before the process temperature. Bearings running hot are the most common cause of unplanned shutdown.

Thermal expansion mismatch

Rotating and stationary parts grow at different rates during heat-up and cool-down. Alignment that was perfect cold can be badly off at operating temperature.

Salt freezing on stop

Solar salt freezes near 238 °C. Any pocket that is not drained or heat-traced can solidify on shutdown and block the next start.

Thermal cycling fatigue

Daily solar cycles mean repeated heat-up and cool-down. Materials and joints must be chosen for fatigue life, not just peak temperature.

B

The engineering response

A genuine ultra-high-temperature molten salt pump is designed from the ground up. These are the four levers that separate a 700 °C machine from a uprated 400 °C one.

1. Advanced high-temperature metallurgy

Nickel-base alloys and specially formulated heat-resistant stainless steels replace standard grades in the wetted end. Controlled grain structure keeps dimensions stable over long runs, and material is selected against the actual salt chemistry and temperature profile rather than a generic catalogue.

2. Hydraulics tuned for dense salt

Smooth, open flow passages reduce turbulence and local hot spots; impeller geometry is designed for high-density molten salt rather than water. The result is stable performance even when temperature and viscosity swing across the operating window.

3. Thermal isolation & expansion control

Thermal barrier zones protect the bearing housing and motor. Axial and radial growth is managed deliberately, and precision alignment is maintained through every heat-up and cool-down cycle — not only at the cold condition.

4. Sealless or special sealing + monitoring

Sealless arrangements or purpose-built high-temperature seals follow a zero-leakage design philosophy for safety-critical service. Optional condition monitoring tracks temperature and vibration so drift is caught before it becomes a failure.

ZGPV workshop manufacturing high-temperature molten salt pumps for 700C service
Every high-temperature pump starts as a duty-point and materials study, not a stock model.
C

Where ultra-high-temperature pumps are specified

In these projects a pump failure is not a maintenance inconvenience — it directly affects plant availability, energy output and the economics of the whole storage system.

Tower-type CSP plants

High-flux receivers push salt temperatures upward; hot-salt circulation and receiver feed pumps run continuously at the top of the temperature envelope.

Long-duration TES (≥10 h)

Bigger tanks and longer discharge windows demand higher flow and tighter efficiency, so pump sizing has an outsized effect on stored-energy cost.

Hybrid & grid peak-shaving

Solar-plus-fossil and renewable hybrid stations cycle hard; pumps must tolerate frequent starts while holding efficiency across a wide duty range.

Further reading: the US Department of Energy's Concentrating Solar Thermal Power programme and SolarPACES describe why high-temperature pumping is critical to next-generation power systems. ZGPV's design approach is summarised here in our own words.

09
Applications

Where molten salt pumps earn their keep

Any process that stores or moves heat in molten salt needs a pump that can live with the temperature. Our vertical high-temperature molten salt pumps, hot salt circulation pumps and chemical molten salt transfer pumps are built for the duties below — and for the many variants in between. If your process uses a nitrate, nitrite or carbonate salt above 150 °C, there is a ZGPV molten salt pump configuration for it.

Concentrating solar power (CSP)

Cold- and hot-salt circulation in two-tank thermal storage, receiver feed and steam-generator supply for parabolic trough and power-tower plants. Long campaign life and resistance to daily thermal cycling are the design drivers.

Chemical process heat

High-temperature heat-transfer loops for melamine, phthalic anhydride, salt making, caustic/alkali and other nitrate-salt heated reactions — where a molten salt pump doubles as a chemical transfer pump.

Industrial thermal storage

Off-peak electric heating into a salt store, then controlled heat release for process steam or district heat. The pump must handle both the charge and discharge circuits without freeze-up.

Read more in our technical articles: Understanding the multistage molten salt pump and More about high-temperature molten salt pumps.

Long-shaft vertical molten salt pumps in ZGPV assembly hall
CSP hot salt service — vertical wet-pit pumps built for continuous high-temperature circulation.
Discharge head and pump body of a vertical high-temperature molten salt pump
Discharge head — cooled, self-draining head keeps bearings and seal away from the salt.
Long column pipe and line shaft bundle for a deep-tank molten salt pump
Deep column — long line-shaft assemblies for deep tanks and receiver feed.
Industrial heat transfer molten salt pump in chemical process heating plant
Industrial heat transfer — nitrate / nitrite salts for chemical process heating up to 850 °C.
Vertical molten salt pump for thermal energy storage charging and discharging
Thermal storage — charging and discharging a molten salt heat store.
Series production of vertical molten salt pumps in ZGPV workshop
Series production — identical mechanical design across the range for easy spares.
B
In context

Molten salt pumps in the wider energy system

Beyond the pump itself, these images show the systems our molten salt circulation pumps serve — concentrating solar power, two-tank thermal storage and high-temperature heat transfer. Images are illustrative references from ZGPV project archives and public solar-energy sources.

Chemical process plant using high-temperature molten salt heat transfer pumps
Chemical process plant — Process plant where molten salt heat transfer and high-temperature chemical transfer pumps are used.
Molten salt thermal storage tank at a concentrating solar power plant
Molten salt thermal storage tank — A large insulated molten salt storage tank at a CSP plant — the kind of tank our vertical pumps circulate.
ZGPV engineers designing molten salt pump configuration at drawing review
Engineering & design — P&IDs and duty datasheets are where every molten salt pump specification begins.
Industrial metal pipework and valves in a high-temperature process plant, typical molten salt transfer piping service
Industrial pipework — High-temperature industrial piping and valves — the service environment of a molten salt transfer pump.
ZGPV technician inspecting a large pump casing during quality control and dimensional verification
Testing & inspection — Engineers review dimensions and test data before a pump is released for hot-salt service.
Solar collector field feeding a concentrating solar power molten salt loop
Solar collector field — Solar field feeding the molten salt loop; heat is stored in salt for dispatch after sunset.
Solar power tower receiver field with concentric heliostat mirrors feeding a molten salt receiver
Solar power tower field — Heliostats concentrate sunlight onto a tower receiver where molten salt is heated before storage. See ZGPV's multistage molten salt pump reference.
Aerial view of a circular heliostat solar collector field for concentrating solar thermal power generation
Heliostat collector field — The surrounding mirror field defines the hot-salt circulation duty that vertical molten salt pumps serve; see more about high-temperature molten salt pumps.
Concentrating solar power tower plant with heliostat receiver field and molten salt thermal storage
CSP plant configurations — Tower and trough plants both rely on molten salt pumps to move stored heat to the steam generator.
10
Manufacturing & testing

Built, cooled and run-tested before it ships

A pump that will spend its life at 400–565 °C cannot be treated like a water pump. Material traceability, casting quality, rotor balance and a witnessed performance test are part of the build, not an optional extra.

In the workshop

  • EN 10204 3.1 / 3.2 material certificates for wetted parts
  • MSS SP-55 visual inspection and MT/PT on castings
  • Rotor dynamic balance to ISO 21940 G2.5
  • Critical-speed and lateral-vibration analysis of the long shaft
  • Hydrostatic test at 1.5 × MAWP; performance test to ISO 9906
  • Dimensional check of submergence and setting depth against the tank drawing
Machined impeller and bowl being assembled in ZGPV workshop
Wet-end assembly — impeller, bowl and wear rings prepared for a high-temperature build.
B

Quick troubleshooting guide

SymptomLikely causeAction
Low flow / headInsufficient submergence, vortex, worn wear ringsRaise level, check bell mouth, measure clearances
Bearing temperature highCooling failure, misalignment, high thrustCheck cooling circuit, coupling alignment and thrust setting
Packing leaks or smokesDry running, wrong packing, salt crystallisingVerify flush, repack with graphite-free packing, warm the gland
Vibration risingShaft bow, bearing wear, operation near critical speedCheck runout, inspect line bearings, review speed range
Won't start after shutdownSalt frozen in the columnApply trace heating and preheat to above freezing before start
Workers assembling vertical molten salt pumps in ZGPV workshop
Assembly hall — pumps laid out for rotor insertion, column build and head fitting.
Inspection of a long-shaft molten salt pump assembly before shipment
Line-shaft inspection — straightness, run-out and bearing fit checked before closing.
Impeller vanes of a vertical molten salt pump close-up
Hydraulic check — impeller and bowl profiles verified against the approved drawing.
Internal assembly and product-lubricated bearings of a vertical molten salt pump
Internals — product-lubricated bearings and renewable sleeves fitted.
Sectional engineering drawing of a molten salt pump
Design review — thermal and mechanical checks precede every build.
Finished long-shaft vertical molten salt pump assembly on the ZGPV workshop floor
Final configuration — the completed pump assembled and ready in our workshop.
11
See it installed

Molten salt pump installation on video

Watch a vertical high-temperature molten salt pump being installed in a concentrating solar power plant — from the workshop to the tank. The clip plays inline when you click the cover; the player loads from YouTube on demand. It is the same installation procedure our engineers follow on every CSP molten salt pump project.

Installation of a Vertical Molten Salt Pump in a CSP plantFrom ZGPV's own channel — the vertical long-shaft molten salt pump lifted, set on the tank and connected for high-temperature nitrate service. Watch on YouTube ↗

ⓘ The player streams from youtube.com. If your network blocks YouTube and the window stays blank, open the direct link above — it opens the video on YouTube. More technical notes: molten salt pumps in CSP.

12
FAQ

Questions we answer every week

What temperature can a molten salt pump handle?

Our vertical high-temperature molten salt pumps are rated up to 850 °C for the medium, with a design pressure up to 7.5 MPa. In CSP service the practical window is set by the salt itself: solar salt runs around 290–565 °C, HITEC around 150–450 °C. The motor and thrust bearing stay outside that envelope, cooled at the discharge head.

Why choose a vertical long-shaft design instead of a horizontal pump?

Because it removes the hot liquid from the seal and bearings. The wet end is submerged in the tank and the driver sits on the tank cover, dry and cool. It also avoids a flooded suction on a hot tank and lets the pump drain back fully — important when a frozen low point can wreck a shutdown.

Which salt — solar salt or HITEC?

Solar salt (60% NaNO₃/40% KNO₃) is the standard for large CSP thermal storage; it freezes near 238 °C and needs careful heat tracing. HITEC freezes near 142 °C and is often chosen for lower-temperature or test-loop duties, though its nitrite content needs attention in material selection. We build for both.

Do these pumps follow API 610?

The multistage and high-pressure builds follow API 610 design practice, and we list every deviation. Testing and acceptance are commonly agreed to Hydraulic Institute standards and ISO 9906. Pressure piping can be designed to ASME B31.1 where the EPC requires it.

How do you protect the pump when the plant shuts down?

By making the wetted end fully self-draining, specifying steam or electric trace heating on the head and external piping, and giving clear preheat and restart procedures. Correct minimum submergence also prevents vortexing as the tank level falls.

What materials are used for the wetted parts?

Typically WC6 cast chrome-moly for bowls and impellers, a strengthened 4140-type shaft, and A106 Gr B column, with upgrades to CF8M, duplex, 17-4PH or A335 P11/P22 depending on salt chemistry and temperature. Graphite is avoided anywhere it could contact the salt.

Can you build to a specific tank nozzle and duty?

Yes. Nozzle class and orientation, mounting plate to interface drawing, column length to tank floor, materials and instrumentation are all engineered to order. Send the tank drawing and duty datasheet for a sized proposal.

What is the difference between a hot salt pump and a cold salt pump?

In a CSP two-tank system the hot salt pump moves salt around 565 °C from the hot tank to the steam generator, while the cold salt pump handles ~290 °C salt returning to the receiver. The hot-salt pump is the more severe duty: higher temperature, larger thermal transients and more demanding material and sealing requirements. We design both from the same vertical platform so spares can be shared.

Can a molten salt pump be used for HITEC salt as well as solar salt?

Yes. Our high-temperature molten salt pumps handle both solar salt (60% NaNO₃/40% KNO₃) and HITEC (7/53/40 nitrate/nitrite). HITEC freezes near 142 °C, so it is more forgiving during shutdown, but its nitrite content is checked in the material selection. Tell us the exact analysis and temperature range and we will confirm the wetted materials.

How do you prevent the salt from freezing when the plant stops?

Three ways: the wetted end is fully self-draining so salt cannot sit in a low point; the discharge head and external piping can be steam- or electric-trace-heated; and we supply a written preheat and restart procedure. Correct minimum submergence also stops vortexing as the tank level falls. This is part of every molten salt pump proposal, not an afterthought.

Do you provide CE marking and material certificates for export?

Yes. Pumps placed on the EU market can be supplied with an EU Declaration of Conformity and technical file to the Machinery Regulation (EU) 2023/1230, pressure-equipment documentation to PED 2014/68/EU, and LVD / EMC for the motor and instrumentation. Wetted parts come with EN 10204 3.1 certificates (3.2 for pressure parts) on request.

Send us your salt, duty point and tank drawing

Tell us the salt composition, temperature, flow and head — or just share the process data you have. Our engineers reply with a sized molten salt pump proposal, performance curve and quotation, typically within a few working days.

Contact ZGPV ↗  Molten salt product page ↗

What to include for the fastest quote

  • Salt type & analysis: solar salt, HITEC, chlorides, particulates
  • Duty: flow (m³/h), total head (m), minimum continuous flow
  • Temperature: normal, maximum upset and ambient
  • Tank drawing: diameter, lowest level, nozzle & setting depth
  • Standards: API 610, ISO 9906, material certs, witness test